Section 5
MLSM2003-09-03
16
Procedure H
- Cooling Fan & Limit
Step 1: Disconnect power supply to
range. Pull range away from wall
and remove backguard held by 3
screws and washers. See Proce-
dure A Step 1.
Step 2: Remove range’s back panel
(See procedure xxx)
Step 3: Test continuity across
cooling fan’s terminals (pull black
and red wires). If fan test in good
condition, test wiring.
Step 4: To test wiring, place
multimeter probe on each wire and
test for continuity between fan and
terminal block and to fan limit.
Step 5: To access fan limit. Prop
Top Up. See Procedure XXX.
Step 6: If fan and wiring in good
condition, test fan limit for continu-
ity. Remove both red wires and test
across, limit should be open and no
reading taken across terminals.
Step 7: If limit test in good condi-
tion, inspect self clean assembly
microswitch (see Procedure C).
Step 8: If limit is faulty, replace.
remove wires to limit and transfer
red wires to new temperature limit.
Step 9: Remove one nut/bolt
holding limit to mounting bracket.
Note: Please ensure that red wires
do not run parallel with coaxial timer
cable or oven thermostat probe
when finished.