Section 5
15
MLSM2003-09-03
Procedure G
- Timer Coaxial Cable
Step 1: Disconnect power supply to
range. Pull range away from wall
and remove backguard held by 3
screws and washers. See Proce-
dure A Step 1.
Step 2: Prop Top Up. See Proce-
dure P.
Step 3: Inspect cable for visible
damage and replace as needed. If
timer does not operate properly,
one of probable components is the
coaxial cable (other probable
components are the timer and the
relay board)
Step 4: Pull locking tabs away and
release cable from relay board.
Step 5: Release coaxial cable from
timer (see Procedure B for timer
access).
Step 6: Replace cable - please
cable is routed exactly as it was
and that it does not interfere with