![HDG Turbotec 50 L Скачать руководство пользователя страница 75](http://html.mh-extra.com/html/hdg/turbotec-50-l/turbotec-50-l_operation-manual_2112431075.webp)
7 Cleaning and maintaining the heating system – Cleaning and maintenance schedule
75
7 Cleaning and maintaining the
heating system
G
ENERAL
To ensure fault-free operation, certain cleaning and maintenance
work is necessary. This effort will help you avoid expensive repairs,
provided you maintain the recommended intervals.
The twice yearly and longer term cleaning and maintenance work
can be covered by a maintenance contract with an authorised
heating engineer.
R
EPLACEMENT
PARTS
7.1 Cleaning and maintenance schedule
Only use original HDG replacement parts! You can obtain HDG
replacement from your specialist heating company.
The specified cleaning intervals are a guideline.
Depending on the quality of the fuel and the power used by the
heating system, the intervals may be extended.
Interval
Component
See page ...
Weekly / as required
•
Cleaning the primary air inlets, fuel chamber
and burner nozzle
•
Cleaning the flame channel and ash
compartment
Monthly (during the heating
period, approx. 240 operating
hours)
•
Cleaning the heat exchanger surfaces
Biannually (approx. 900
operating hours)
•
Cleaning the flue pipe
•
Checking and cleaning the lambda sensor
•
Cleaning the flue sensor
•
Checking and cleaning the flue gas fan
•
Lubricating the door latch bolts
•
Checking and cleaning the flue bypass damper
Annually (approx. 1800
operating hours)
•
Cleaning the control unit
•
Inspecting and cleaning the air control units
•
Inspecting the integrity of the door seals
•
Calibrating the lambda sensor
Table 7/1 - Cleaning and maintenance schedule