33
WE2108
HBM
A1632-2.0 en
5.2.3
Complete menu structure
”Information” submenu
ENTER
CE
NEXT
UP
Para-
meter
Meaning
Value range
Remarks
CHEC
Calibrtation counter
0 ... 99999
only display
tArE
Current tare value
0 ... 99999
Display of the current tare
value.
Change under ”P_tAr”
S_Ver
Software version
only display
F_nb
Production number
only display
Err
Last occurring error code
0 ... 99
only display
OV_Ld
Scale counter overload
(130% MAX)
0 ... 99999
only display
P_tAr
Preset tare value
0 ... 99999
Appears only with preset
tare function activated
(
Func
menu)
”Limits” submenu
ENTER
CE
NEXT
UP
Para-
meter
Meaning
Value range
Remarks
P1_Fu
Limit 1 function
0: off
1: limit related to gross
2: limit related to net
P1_Lo
Limit output 1 logic
0: active = open,
1: active = Ground
P1_On
Switch−on value 1
P1_OF
Switch−off value 1
for setting a hysteresis
P2_Fu
Limit2 function
0: off
1: limit related to gross
2: limit related to net
P2_Lo
Limit output 2 logic
0: active = open,
1: active = Ground
only display
P2_On
Switch−on value 2
P2_OF
Switch−off value 2
for setting a hysteresis