22
WE2108
HBM
A1632-2.0 en
The unit is mounted in the following steps:
1. Remove the mounting base from the back of the housing after loosening
two screws.
2. Fasten the mounting base to the stand plate with four screws with a diame-
ter of 4 mm.
3. Run cables through the PG glands and connect to the electronic unit.
4. Close the housing halves and connect with two screws. In this case pull the
cables still a little out from the PG glands.
5. Fasten the closed housing to the mounting base with two screws. In this
case possibly run the cables into the inside of the stand tube.
4.3
Use as desktop unit
(WE2108 in a plastic housing)
The WE2108 is provided with four rubber feet for installing on horizontal sur-
faces. These generally guarantee safe standing and prevent slipping away
when operating the keys.
Moreover fastening in the same way as in wall mounting is possible. If the
mounting surface is accessible from below, the holes for stand mounting can
also be used. If the feet remain on the unit in this case, take care that the
mounting base is not stressed by tightening the screws too firmly.
For inclination of the operating area towards the user, the mounting base must
be installed with the curved part upwards.
4.4
Wall mounting / desktop unit
(WE2108S in a stainless steel
housing)
The unit is wall−mounted by means of two bolts, or it can be used as a desk-
top unit. See ”Dimensions WE2108S / WE2108M (Stainless steel housing)”
on page 72.
4.5
Control panel assembly
(WE2108M in a stainless steel housing)
The unit is assembled into a control panel by means of six bolts. See ”Dimen-
sions WE2108S / WE2108M (Stainless steel housing)” on page 72.
WARNING
The protection class IP65 for type WE2108M only applies to the front!