18
WE2108
HBM
A1632-2.0 en
3.2.4 Process
Outputs
Terminal PC board legend
Function
Example of connection
7
Pout3
not used
Pout3
GND
Pout2
GND
Pout1
GND
Supply for
switched loads
+
−
8
GND
Ground
9
Pout2
Process output 2
!
)
10
GND
Ground
11
Pout1
Process output 1
!
)
12
GND
Ground
!
)
open−collector to ground, (external) U
max
= 45 V, I
max
= 200 mA typ. (electronically protected). When con-
necting magnetic articles (e.g. relays), a free wheeling diode must be connected parallel to the coil.
3.2.5
WE2108 operating voltage
Terminal PC board legend
Function
Remarks
13
+DC
Operating voltage
+10−35 V DC
@
)
14
GND
Ground
@
)
The supply voltage must be filtered sufficiently (rms value less residual ripple > 10V).
3.2.6 Process
Inputs
Terminal PC board legend
Function
Example of connection
15
Pin1
Process input 1
#
)
+DC
GND
Pin1
GND
Pin2
GND
16
GND
Ground
17
Pin2
Process input 2
#
)
18
GND
Ground
#
)
Actuate by switching to ground, max. voltage 35 V.