Damage to the lamp cable may have a detrimental effect on lamp output. Verify the
lamp cables are free of any significant damage.
Inspect lamp connections & cable for damage. IF
damaged, replace cable (
HYXSLACA
). IF not damaged,
go to 1H.
Power the HydroRite down & replace the lamp(s)
(
HYX2DLAS
). It is recommended to replace lamps in
threes.
Verify Lamp Connection/Cable
Step 1G
Step 1H
Replace lamp(s)
31
NOTE: It is recommended to replace lamps in sets of three. IF all three lamps are
replaced, then it is prudent to calibrate the HydroRite. IF only 1 or 2 of the lamps are
replaced, DO NOT calibrate the unit.