CAUTION: Transformer output is 240VAC!
Verify transformer output is 192-288VAC. IF the voltage
is correct, replace the interconnect board (
HYX2CSIPCB
).
IF NO/LOW, go to 2F.
Verify transformer input is 108-132VAC between pins 1-
3 & 2-4. IF OK, replace transformer (
HYX2C-XFMR
). IF
NO/LOW, go to step 2G.
Test Transformer Output
Step 2E
Step 2F
Test Transformer Input
35
2. Display Not Lit (cont.)