Test the two interconnect fuses for continuity. These
fuses protect the interconnect board’s power circuit. IF
fuse(s) is/are blown, proceed to step 2H. IF fuses are
not blown, jump to step 2I.
On the interconnect board, verify the voltage selector is
set to 115V
*
. Once confirmed, replace both fuses
(
HYX2CFK25
) & retest. IF fuse immediately fails again,
replace the board (
HYX2CSIPCB
).
Test Interconnect Fuses
Step 2G
Step 2H
36
2. Display Not Lit (cont.)
Verify Voltage Selectors (intercon.)
There are two voltage selector plugs: the one located on the main (green) board,
should be set to 230V and the one on the interconnect (blue) board, should be set to
115V. If either of these are incorrect, fuses on the corresponding board may blow.
*NOTE: IF the voltage selector is covered by the following
label, DO NOT remove the label & consider the voltage
selector confirmed.