![Hayward hydrorite uvo3 Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/hayward/hydrorite-uvo3/hydrorite-uvo3_troubleshooting-manual_2111082041.webp)
IF the ‘FLO’ error persists despite running the pump and isolating out the interlock
switch, then the inline flow sensor is likely the cause of the error. IF isolating the
interlock switch clears the error, then the problem is related to the interlock circuit.
Replace the inline flow switch with the new flow
switch. Then restore the interlock switch connection on
the main panel. Turn the pump back on & wait 3
minutes. IF the error still appears, jump to step 3G to
troubleshoot the interlock switch.
Unplug the new flow switch (used in step 3D) & plug
the interlock switch back into the main panel. The
inline flow switch has been confirmed. Proceed to step
3G to troubleshoot the interlock switch & its cable
connections.
Replace Flow Switch & Restore
Step 3E
Step 3F
Restore Interlock Switch