![Hayward hydrorite uvo3 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/hayward/hydrorite-uvo3/hydrorite-uvo3_troubleshooting-manual_2111082030.webp)
NOTE: Ballasts should be plugged into the interconnect board via terminals 1, 3, & 5.
Verify the ballasts are plugged into these positions before proceeding.
Inspect the ballast LEDs. IF there are NO LEDs
illuminated, procced to step 1F. IF the LEDs are
illuminated in RED, proceed to step 1G.
Verify 216-264VAC present on the PCB. IF NO/LOW
voltage replace the interconnect PCB (
HYX2CSIPCB
). IF
correct, replace ballast (
HYXSBCHA
).
Inspect Ballast LEDs (cont.)
Step 1E
Step 1F
Verify Ballast Input Power
30
1. ‘SYS ERR’ Appears on Display (cont.)