1. ‘SYS ERR’ Appears on Display
‘SYS ERR’ on
Display
Clean Quartz
Sleeve & Lamp
Sensor
After 30 mins.
does ‘SYS ERR’
still appear?
YES
NO
Are LEDs ON
at all?
Inspect the
lamp cable
connections
Are ballast
LEDs ON in
Green?
YES
NO
Verify LEDs
on ballasts
27
Are they
correct?
YES
Verify 216-264VAC
present on the PCB
Reseat &
retest
YES
NO
Run time
exceeds
9,000 hrs.?
Are voltage
readings
correct?
Replace
lamps
NO
Replace
Interconnect
PCB
Problem
solved
Is chemistry
balanced?
NO
YES
Balance
& retest
Check lamp
‘run’ hours
Contact Tech
Support:
(908) 355.7995
NO
Replace
ballast(s)
YES
YES
NO
Are cables
damaged?
Replace
lamp cables
YES
NO
Replace all
lamps &
calibrate
Содержание hydrorite uvo3