38
3. ‘FLO’ Appears on Display
Pump is
running?
YES
Flow is a min.
of 15GPM
*
?
NO
Turn on
pump, after 3
mins did ‘FLO’
clear?
YES
Is filter
clean?
Clean filter
& retest
YES
‘FLO’
Appears
Problem
solved
NO
YES
*NOTE: 15GPM is enough to satisfy the flow switch requirement, but not enough for Ozone infusion,
which requires 38GPM minimum.
Plug a new flow
switch into the
interlock port
Turn pump on
& close new
flow switch,
does the error
clear?
NO
NO
Plug interlock switch
back in & replace the
existing flow switch,
turn on pump, did
the error clear?
YES
NO
Check
interlock
cable, is it
damaged?
YES
Problem
solved
Contact tech
support:
(908) 355-
7995
NO
YES
Is interlock
connection
secure?
Secure
connection &
retest
NO
YES
Replace
interlock
switch
assembly
Increase
pump speed
& retest
NO
Unplug new
flow switch &
restore
interlock
connection
Содержание hydrorite uvo3
Страница 7: ...HydroRite UVO3 Overview ...
Страница 10: ...10 HydroRite Vessel Top ...
Страница 17: ...HydroRite UVO3 How To ...
Страница 26: ...HydroRite UVO3 Troubleshooting ...
Страница 52: ...HydroRite UVO3 Additional Information ...