Chapter 3 System Installation with the Content-
Server 3000 Series
© 2017 Harmonic Inc. All rights reserved.
101
Harmonic MediaGrid Release 4.1
Connecting the Harmonic MediaGrid 3000 System Components
IMPORTANT:
If you are supplying your own network switches, make sure to use only Harmonic
MediaGrid-qualified switches in your Harmonic MediaGrid system. To find out if a switch is Harmonic
MediaGrid-qualified, contact your Harmonic representative.
Figure 3–30: Network Switches and Client Network Connections
Connecting Components in Rack One
To connect the network switches to the client network:
1. Connect CX4 cables to the two 10 GbE ports on the back of rack one’s first switch. Connect
the other end of the cables to available 10GbE ports on rack two’s switch that connects to the
client network.
2. Connect CX4 cables to the two 10 GbE ports on the back of rack one’s second switch.
Connect the other end of the cables to available 10 GbE ports on rack one’s switch that
connects to the client network.
3. Connect the top network switch to the client network.
Connecting Components in Rack Two
To connect the network switches to the client network:
1. Connect CX4 cables to the two 10GbE ports on the back of rack two’s first switch. Connect
the other end of the cables to available 10GbE ports on rack two’s switch that connects to the
client network.
2. Connect CX4 cables to the two 10 GbE ports on the back of rack two’s second switch.
Connect the other end of the cables to available 10 GbE ports on the back of rack one’s
switch that connects to the client network.
3. Connect the top network switch to the client network.
4. Continue with
Connecting the Power Cables in a System with ContentServer 3000 Series
to complete
the hardware installation.
Connecting the Power Cables in a System with ContentServer 3000 Series
With all of the network cable connections completed, connect the power cables as detailed in the
following order.
10GbE Switch
To Client Network
10GbE Switch
To Client Network
First Switch
Second Switch
First Switch
Second Switch
Rack Two
Rack One