Chapter 3
Control input/output
- -
13
CN1-5
Servo on
: ENABLE
◆
Functions
(1) This signal turns on/off the driver circuit of the HS-360 driver.
When this input is on, the driver servo goes on, causing the driver to be ready. When it is off, the
servo goes off, causing the servo to be free, or the dynamic brake to be active.
(2) The dynamic brake on/off selection can be made by selecting [Parameter setup mode]
→
[46:
Dynamic brake on/off].
(3) The logic can be changed by selecting [Parameter setup mode]
→
[38: Input pin logic]. The default
is 0 (CLOSE), and the signal is meaningful.
(4) If [Parameter setup mode] is selected and 1 is selected in [41: CLEAR signal functions], the error
counter is also cleared and the error pulse count is set to 0.
◆
Connection
(1) For the input circuit power supply, prepare DC 24V separately.
(2) The input current is at approximately 10mA per circuit.
CN1-6
alarm reset
: ALM-RST
◆
Functions
(1) When an alarm occurs
The alarm is cleared, and the driver is made ready. The edge is used for detection. If an
unclearable alarm occurs, turn off the power once. In this case, turn the power on again after
removing the cause of the alarm.
(2) The logic can be changed by selecting [Parameter setup mode]
→
[38: Input pin logic]. The default
is 0 (CLOSE falling edge), and the signal is meaningful.
(3) If [Parameter setup mode] is selected and 1 is selected in [41: CLEAR signal functions], the error
counter is also cleared and the error pulse count is set to 0.
Connection
(1) For the input circuit power supply, prepare DC 24V separately.
(2) The input current is at approximately 10mA per circuit.
CN1-7
error counter clear
: CLEAR
◆
Functions
(1) Clear the error counter, and set the error pulse count to 0.
(2) The logic can be changed by selecting [Parameter setup mode]
→
[38: Input pin logic]. The default
is 0 (CLOSE falling edge), and the signal is meaningful.
(3) If [Parameter mode] is selected and 0 is selected in [41: CLEAR signal functions], this input signal
will be enabled. If 1 is selected there, it will be disabled.
◆
Connection
(1) For the input circuit power supply, prepare DC 24V separately.
(2) The input current is at approximately 10mA per circuit.