Chapter 5
Operations
- -
32
Chapter 5 Operations
Follow these instructions prior to operations.
5-1 Trial
run
Drive the actuator only without load during the trial run.
●
Objectives for the trial run
(1)
Verifying the power cable wiring
(2)
Verifying the motor cable wiring (the servomotor cable and the encoder cable)
●
Trial run procedure
◆
Powering on the driver and checking the power supply, motor, and encoder wiring
(1) Power on the driver
☺
Check that no failure has occurred.
⇒
The state data mode display appears on the HS-360 driver.
1. Inspect the cabling before turning the power ON and correct
poor cabling if necessary.
(1) Is the cabling correct?
(2) Is there any temporary cabling? Are all wires connected to the
terminals?
(3) Are there any loose terminal connections?
(4) Are the wires grounded properly?
2. Never wire the unit or make changes to the wiring while the power is ON.
Turn the power OFF first.
3. Clean around the equipment. Make sure there are no wire chips or tools in
the equipment.
1. Complete the trial run before actual operation.
2. Drive the actuator only during the trial run; disconnect the actuator from
the driven mechanism or load.
Caution
Warning