Hardy 1734-WS Installation & Operation Manual
Page | 12
The base (A) mounts onto the DIN rail and provides the backplane. The
HI1734-WS POINT I/O module (B) snaps into the base. The removable
terminal block (C) also snaps into the base and provides the wiring and
terminations for field-side connections, as well as system power for the
backplane. For best performance, Hardy recommends use of 12-slot
screw-down terminal. Spring clamp blocks are only recommended
when using solid-core wiring.
To remove, simply move the Clip (D) into the downward position and
pull the HI1734-WS out of the base.
For detailed installation instructions for the POINT I/O system, please
visit:
http://literature.rockwellautomation.com/idc/groups/literature/doc
uments/sg/1734-sg001_-en-p.pdf
Load Sensor Connections
The HI 1734-WS weigh scale module will need to be connected to
external sensors, whether a single load sensor connected directly, a
group of load sensors connected through a Junction Box or a platform
scale such as a bench or floor scale connected direction. Each has its
own wiring configuration.
Below are various connections for different types of sensors and
different POINT I/O Terminal Blocks.
HI 1734-WS Weigh Scale Module Wire Terminations to Hardy Junction Boxes
SCREW DOWN TERMINALS RECOMMENDED