Supplied By www.heating spares.co Tel. 0161 620 6677
1
TECHNICAL SPECIFICATIONS
2
HALSTEAD Finest Platinum
2.2
PERFORMANCE DATA
Central
Max 24.9 (85000) 27.4 (93455) 30.4 (103725)
9.0
(3.61)
Heating Min. 14.6 (49,747) 16.4
(55,957) 18.2
(62098)
3.0
(1.2)
DHW
Max 32.2 (110000) 35.7 (121740) 39.6 (135115)
15.5 (6.23)
Min. 9.0 (30844) 10.7 (36577) 11.9 (40603)
1.0 (0.4)
MODE RA
TE OUTPUT
INPUT INPUT
BURNER
Net
Gross
PRES
kw (Btu/h) kw (Btu/h) kw (Btu/h)
mbar (in.wg)
HALSTEAD Finest Platinum Propane
Central
Max 24.9 (85000) 27.4 (93455) 29.8 (101678)
17.0
(6.83)
Heating Min. 14.6 (49,747) 16.4
(55,957) 17.8
(60734)
5.8
(2.33)
DHW
Max 29.3 (100000) 32.4 (110480) 35.2 (120068)
23.4 (9.40)
Min. 9.0 (30844) 10.7 (36577) 11.7 (39750)
2.3 (0.92)
MODE RA
TE OUTPUT
INPUT INPUT
BURNER
Net
Gross
PRES
kw (Btu/h) kw (Btu/h) kw (Btu/h)
mbar (in.wg)
1
GENERAL
CH
DHW
Max. gas rate (after 10 mins operation i.e. hot)
2.90 m
3
/h (102.3
ft
3
/h)
Min. domestic hot water flow rate
2.1 l/min
(0.46 gpm)
Design domestic hot water performance
13.2 l/min (2.9 gpm) raised 35°C
Specific DHW flowrate (EN625)
15.4 l/min
Max. domestic hot water temperature
60 °C
Max. mains water inlet pressure
10 bar
(146 psi)
Min. mains water inlet pressure for operation
0.3 bar
(4.4 psi)
Min. mains water inlet pressure for max heat output
1.0 bar
(14.6 psi)
Max. gas rate (after 10 mins operation i.e. hot)
3.77 m3/h
(133 ft3/h)
GENERAL
CH
DHW
Max. gas rate (after 10 mins operation i.e. hot)
1.12 m
3
/h (39.6
ft
3
/h)
Min. domestic hot water flow rate
2.1 l/min
(0.46 gpm)
Design domestic hot water performance
12.0 l/min (2.6 gpm) raised 35°C
Specific DHW flowrate (EN625)
14.0 l/min
Max. domestic hot water temperature
60 °C
Max. mains water inlet pressure
10 bar
(146 psi)
Min. mains water inlet pressure for operation
0.3 bar
(4.4 psi)
Min. mains water inlet pressure for max heat output
1.0 bar
(14.6 psi)
Max. gas rate (after 10 mins operation i.e. hot)
1.33 m3/h
(47.0 ft3/h)
.
.
.
.
.
.
.
.
.
. .
.
.
100mm DIA
.
365mm
200mm
210mm
760mm
455mm
900mm
100mm
.
.
.
1(a)
200mm
200mm
5mm
5mm
SEE
NOTE
•
•
•
•
•
•
•
•
••
The appliance is cer
tified to comply with the requirements of EN 483 and
EN 625 for use in GB and IE (Great Britain and Ireland) using the
following gas categories:
Finest Platinum: I2H (G20 with a governed gas supply at 20 mbar (8
in.wg) inlet pressure).
Finest Platinum Propane: II2H3P (G31 [Propane] with a regulated supply at
37 mbar (14.9 in.wg) inlet pressure)
The appliance classification (as defined in EN 483) may be any of the
following depending on the chosen flue option: C12 or C32.
2.1
GAS CATEGORIES AND
APPLIANCE CLASSIFICATION
2.3
MINIMUM CLEARANCES
Main bur
ner injector (NG)
1.35 mm Ø x 13
Main burner injector (Propane)
0.90 mm Ø x 13
Total water capacity
1 litre
Minimum CH system pressure (static head) – Cold
0.5 bar
Maximum CH system pressure (static head) – Hot
3.0 bar
Empty weight
49.1 kg
Max. lift weight
37.3 kg
Total weight (full)
50.1 kg
Electrical supply
230V 50Hz
Fuse at 3A
Internal fuses
T4H 4A 250V
Maximum power consumption
190 W
Max. CH flow temperature
80 °C
176°F
Integral expansion vessel capacity
8 l
Flue products mass flow rate (NG)
18.3 g/s
Flue products mass flow rate (Propane)
18.8 g/s
Average flue gas temperature (NG)
155 °C
Average flue gas temperature (Propane)
145 °C
CO
2
value (CO)% (max CH output) (NG)
5.6 ± 6% (0.002 ± 10%)
CO
2
value (CO)% (max CH output) (Propane)
6.8 ± 6% (0.001 ± 10%)
CO
2
value (CO)% (max DHW value) (NG)
7.5 ± 8% (0.008 ± 50%)
CO
2
value (CO)% (max DHW value) (Propane)
7.4 ± 8% (0.003 ± 50%)
Minimum clearances for installing and servicing the appliance refer to Fig. 1(b) below.
Gas
15 mm compression
CH flow
22 mm compression
CH return
22 mm compression
DHW inlet
15 mm compression
DHW outlet
15 mm compression
Pressure relief valve outlet
15 mm tail
CONNECTION SIZES
2.4
GENERAL SPECIFICATIONS
1(b)
NOTE:
10mm for normal
operation 450mm for
installation and servicing
The Seasonal Ef
ficiency is 78.7 %, The efficiency value is used in the UK
Government Standard Assessment (SAP) for energy rating of dwellings.
The Seasonal Efficiency is 80.5 %, The efficiency value is used in the UK
Government Standard Assessment (SAP) for energy rating of dwellings.
As natural gas appliances except where stated below
2.5
OVERALL DIMENSIONS AND
MINIMUM CLEARANCES