20
5. Installation (continued)
5-2-1
Attaching the Feeder Unit (CX5005)
1.
Open the cover of the feeder unit (CX5005), attach
the solder feed pulley unit to the feeder unit (CX5005),
and tighten the screws indicated in the diagram.
CAUTION
Do not touch any hexagon socket head cap screw other than those indicated in this manual.
Also, be careful not to overtighten the screws.
The attachment method of the solder feed pulley unit for Φ0.3 mm solder (BX1000) is different.
Refer to “Solder setting method” included with the BX1000.
2.
Remove the hexagon socket head cap screws of
the feeder unit (CX5005).
3.
Use the removed hexagon socket head cap screws
to attach the feeder unit (CX5005) to the soldering
unit fixture base.
Solder feed
pulley unit
Hexagon socket
head cap screw
M3×6 (2)
Tighten
Cover
Hexagon socket
head cap screw
M3×6 (2)
Hexagon socket
head cap screw
M3×6 (2)