Fault
Possible cause
Remedial action
Remedied by
Dirty limit stop area
Remove workpiece end-stop and
clean mating surfaces
Dirty coupling area
on the clamping el-
ement
Remove clamping element; clean
coupling area and clamping ele-
ment
Dirty clamping ta-
per
Remove clamping element and
clean clamping taper
Geometry error on
workpiece due to
incorrect type of
clamping element
Use a suitable clamping element
Flexible distortion
Reduce clamping force to the size
applicable to the clamping device
and the workpiece
Check the workpiece material
Indentations on
the clamping sur-
face
Clamping force is
too high
Reduce clamping force to the size
applicable to the clamping device
and the workpiece
Skilled special-
ist
Wrong type of
clamping element
Use a suitable clamping element
Dirty clamping ele-
ment
Clean the clamping element
Damaged clamp-
ing element
Replace the clamping element
Dimensional differ-
ence between
workpiece diame-
ter and clamp bore
is too great
Use clamping element with suita-
ble clamp diameter
Table 24: Fault table
13.3 Commissioning after a fault has been remedied
After the fault has been remedied, perform the following
steps to recommission it:
1. Reset the emergency stop equipment.
2. Acknowledge the fault on the control unit of the machine
tool.
3. Ensure that no-one is in the danger area.
4. Start the machine tool.