HYDROK
Safety
Order h49 7144.907-333
21
CAUTION
Injuries caused by slipping on escaping media!
Ensure that media are not able to escape.
Drain the rest of the product.
NOTE
Serious damage to materials / the machine tool /
the product caused by workpieces being ejected
centrifugally if clamping is released while they are
still rotating!
Never release the clamping of the workpiece
while it is still rotating.
NOTE
Damage to materials caused by untightening the
wrong screws!
Do not open the screws secured with sealing lac-
quer.
2.7 Screws
WARNING
Serious injuries caused by radially installed
screws being ejected centrifugally if installed in-
correctly / poor handling!
Do not open the screws secured with sealing lac-
quer.
Screws and threaded pins fitted radially to the
product that were bonded with adhesive need to
be secured again using a standard, medium-
strength screw adhesive and tightened to the
specified tightening torque [see nomenclature or
the »Screw tightening torques« chapter]. Before
reinstallation, clean and degrease the screw and
internal thread.
Radially mounted screws and threaded pins that
were not bonded with sealing lacquer or an adhe-
sive need to tightened back down to the specified
tightening torque [see nomenclature or the
»Screw tightening torques« chapter].
If in doubt, contact the manufacturer immediately
to determine how best to proceed.