HYDROK
Maintenance
102
Order h49 7144.907-333
A check is also required to ensure that all fixing screws are
tightened down.
If damage is detected, the relevant components must be ex-
changed immediately for genuine spare parts from the man-
ufacturer.
Complete cleaning of the product is required if heavily soiled
[see »Cleaning« chapter].
11.6 Lubricating the product
DANGER
Serious injuries caused by workpiece being
ejected centrifugally due to insufficient lubrication
of the product!
Never drop below the lower limit value for clamp-
ing force [see »Clamping force diagram« chap-
ter].
Always comply with the maintenance intervals
[see »Maintenance schedule« chapter].
Lubrication takes place every time the system is cleaned,
maintained or assembled, and also when required.
The product is equipped with grease nipples.
WARNING
Collision impact and cut injuries can be caused by
slipping when applying grease with a piston-actu-
ated grease gun!
Ensure that the piston-actuated grease gun is po-
sitioned correctly.
1. With the help of the piston-action grease gun [not in-
cluded in the scope of delivery], squeeze grease into the
grease nipple until no more grease can be injected.
2. At all lubrication points, remove escaping, consumed or
surplus grease, and dispose of it in accordance with lo-
cally enforceable legislative provisions.
3. After lubrication, perform the entire stroke several times.