– 77 –
Fault
Code
Description
Trigger Condition
Action
33, 34,
41, 42,
43, 44,
45, 46,
47, 48,
49, 50,
51, 66,
67, 68,
69, 71,
72, 73,
74, 83
Inverter Fault
Any of these faults can be
set if the inverter board
reports a fault.
• Run Service Mode spin test 14 to full
completion. If cycle fully completes, no
further action required.
• Check line voltage for 102 VAC to 132
VAC.
• Check all inverter board harness
connections.
• Check motor TCO continuity at J502
(inverter board). If open, should reset
after 45 minutes.
• Check for continuity through each
pair of motor phase windings. If any
windings found open, replace motor.
• If the above repair actions don't clear
the fault, replace inverter board.
35, 59,
60, 61,
63, 64
Accelerometer
Faults
Any of these faults can be
set if the accelerometer
board reports a fault.
• Run Service Mode spin test 14 to full
completion. If cycle fully completes, no
further action required.
• Check accelerometer board harness
connections.
• If the above repair actions don't clear
the fault, replace accelerometer board.
37
Heater
Fault is set if the
thermistor doesn't see
at least 3 degrees
Fahrenheit heat rise after
the heater has been on
for 5 minutes.
• Run Service Mode heater and
thermistor test 20 to verify heater and
thermistor.
• Check thermistor resistance from
connector J701 on the control board.
Validate the resistance matches the
table in mini-manual.
• Check the heater resistance from
connector J503 on the control board
from pin 4 to 5.
• Check wiring harness and connections.
• Replace thermistor or heater if
resistance is out of spec.
38, 39,
40, 84
Vent Damper
Fault is set if close/open
feedback is not fails after
5 seconds.
• Run Service Mode damper test 24 to
verify feedback open/close.
• Check wiring harness and connections.
• Replace damper if damper feedback
open/close is not detected.
57
Door Lock
Fault Water
Above Door by
Pressure
This fault is set when
door is unlocking while
water level detected by
pressure sensor is above
than threshold.
• Check pressure tube for trapped water.
• Check each valves operation. (Replace
water valve and send back to GE
Appliances.)
• Use pressure sensor test 10 to ensure
correct pressure sensor operation.
• Check pressure tube for pinches where
it goes through top cover grommet.
• Ensure pressure chamber port is free
from obstruction using drill bit size 1/16-
in. by hand so as not to drill through the
inner wall.
(
Continued next page
)