– 70 –
Test
No.
Test Name
Description
10
Pressure Sensor • Pressing Start/Pause will start the test.
• Door will lock while test is active.
• Pressure sensor test will have a timeout.
• Cold valve will turn on at start of the test.
• The test will watch for the following pressure levels: 3", 4", 5", 6", 7".
• At start of the test, the following LEDs will start blinking: Extra Light,
Light, Normal, Heavy, Extra Heavy.
• As each pressure level is crossed, the corresponding LED will stop
blinking.
12
Drain Pump
•
Pressing Start/Pause will toggle the bulk valve on and off.
• Test will have a timeout for how long valve will be on (1 minute).
•
The valve will turn off when the test is exited.
13
Door Switch
• Pressing Start/Pause will start the test.
• When the door is open, the Soil Level "Light" LED will blink.
• When the door is closed, the Soil Level "Extra Light" LED will blink.
• Closing the door causes another status LED to blink.
14
Spin
• Pressing Start/Pause will start the test.
• Spin test will perform child safety.
• The door must be closed to start the test. If door is open, the lock LED
will blink.
• When started, the mode will shift to spin if required and the door will be
locked.
• When mode shift is complete, the unit will begin spinning.
• Spin test will have a timeout (4 minutes).
• No OOB detection during the spin.
• The spin will stop when the test is exited.
• The door will unlock once the speed reaches 0 after the test is exited.
15
Tumble
• Pressing Start/Pause will start the test.
• Tumble test should perform child safety.
• The tumble will stop when the test is exited.
16
Clear All Fault
Codes
• Pressing Start/Pause will clear all Fault codes.
17
Change
Personality
• Pressing Start/Pause will start the test.
• Pressing the Start pad will display the next valid personality.
• Pressing and holding the Start pad for the selected personality will write it
to NV and reboot.
19
Bulk Detergent
Dispense Valve
•
Pressing Start/Pause will toggle the valve on and off.
• Test requires door to close before beginning. Door will lock while test is
active.
• Test will have a timeout for how long valve will be on (1 minute).
•
The valve will turn off when the test is exited.
(
Continued next page
)