– 71 –
Test
No.
Test Name
Description
20
Heater and
Thermistor
• Pressing Start/Pause will start the test.
• Heater test should perform child safety.
• The door must be closed and locked during the test. If the door is open,
the lock LED will blink.
•
When started, a steam fill routine will be performed.
•
After fill, the heater will turn on and will have a timeout (5 minutes).
• The SSD display will show the thermistor temperature.
21
Prewash Valve
•
Pressing Start/Pause will toggle the valve on and off.
• Test requires door to close before beginning. Door will lock while test is
active.
• Test will have a timeout for how long valve will be on (1 minute).
•
The valve will turn off when the test is exited.
22
Sump Steam
Valve
•
Pressing Start/Pause will toggle the valve on and off.
• Door will lock while test is active.
• Test will have a timeout for how long valve will be on (1 minute).
•
The valve will turn off when the test is exited.
23
Bleach Valve
•
Pressing Start/Pause will toggle the valve on and off.
• Door will lock while test is active.
• Test will have a timeout for how long valve will be on (1 minute).
•
The valve will turn off when the test is exited.
24
Damper
• Pressing Start/Pause will toggle the damper state.
• When the damper feedback indicates that the damper is open, the Soil
Level "Light" LED will blink.
• When the damper feedback indicates that the damper is closed, the Soil
Level "Extra Light" LED will blink.
25
OND Fan
(Overnight Dry)
• Pressing Start/Pause will toggle the fan state.
• When the fan is on, the Soil Level "Light" LED will blink.
•
When the fan is off, the Soil Level "Extra Light" LED will blink.
• Not all models have a fan (only 850 models have fans).
26
Accelerated
Spin Test
• Pressing Start/Pause will start the test.
• Spin test will perform child safety.
• The door must be closed to start the test. If the door is open, the lock
LED will blink.
• Damper must be closed to start ramp up.
• When started, the mode will shift to spin if required and the door will be
locked.
• Spin test will have a timeout (approximately 2 minutes).
• No OOB detection during the spin.
• The spin will stop when the test is exited.
• The damper will be open and door will unlock once the speed reaches 0
after the test is exited.
• Seven Segment Display (SSD) will display the current speed. The SSD
only has 3 digits so the displayed speed needs to be multiplied by 10.
For example, the SSD shows 110 so the speed is 1,100 RPM.