– 65 –
12.
Remove the fifteen 10-mm bolts securing the
tub front half to the tub rear half.
NOTE:
There is a seal between the front and rear
halves of the tub. If the seal is damaged when
separating, replace it.
13. Slide the inner basket out of the rear half of
the tub.
NOTE
: The rear tub seal and bearing are pressed
into the rear half of the tub. To replace them, the
rear tub half will need to be replaced.
14.
The basket baffles can be remove by
removing two Phillips-head screws and sliding
the baffle toward the front of the basket and
pulling out.
15. Disconnect the dispenser vent hose from the
tub (see
Dispenser Assembly Removal
,
under
Dispenser Assembly
in the
Fill
System
section of this service guide).
16. Disengage the two remaining dampers from
the rear half of the tub.
7. Remove the drain hose from the bottom of the
rear half of the tub.
8. Remove the heater assembly from the front
side of the tub (see
Heater Removal
under
Heater Assembly (650 and 850 Models)
in
the
Cabinet and Structure
section of this
service guide).
9. Remove the two front counter weights by
removing the eight 13-mm bolts securing the
weights to the tub; there are four for the top
weight and four for the bottom weight. There
are mounting guide posts molded onto the tub
so the weights will not fall when the bolts are
removed.
CAUTION
: The counter weights are
approximately 15-pounds each, and could cause
injury if dropped on fingers or toes.
10.
Remove the tub fill and the dispense
vent hoses from the tub (see
Dispenser
Assembly Removal
, under
Dispenser
Assembly
in the
Fill System
section of this
service guide).
11. Disengage the front dampers from the tub
(see
Dampers
in the
Suspension and Tub
Assembly
section of this service guide).
(
Continued next page
)