– 33 –
6. Push in on the tab that secures the RJ45
connector to the control panel.
RJ45
Connector
Tab
WARNING
: Sharp edges may be exposed when
servicing the washer. Use caution to avoid injury
and wear Kevlar gloves or equivalent protection.
NOTE
:
Combined Phillips-head and metric
hex-head screws can be utilized throughout this
appliance. Either a Phillips screw-driver or metric
wrench can be used to extract or install these
screws.
Removal of the top panel provides access to the
dispenser, water valves, water level sensor, two
RJ45 connector housings and line filter.
Top Panel Removal
1. Remove the control panel (see
Control
Panel Removal
, under
Control Panel
, in this
section).
2. Remove three Phillips-head screws at the
front of the top cover.
Top Panel
3. Pull the top panel forward to disengage the
rear guide posts and then lift up.
The door is reversible and can be ordered as
a complete assembly (hinge included). The
door hinge is attached to the front panel with six
Phillips-head screws and two hooks that engage
the two cutouts in the front panel.
Door Removal
1. Remove the six Phillips-head screws that hold
the hinge to the front panel. The door will
stay in place.
2. Lift the door and hinge 1/4-inch to disengage
the hinge hooks from the front panel.
Door