I
5
FlexFit Pro
System Type
Wall Mount
Wall Mount
Outdoor
1U24LP2VHA
1U36LP2VHA
Indoor
AW24LP2VH*
AW36LP2VH*
Voltage, Cycle, Phase
V/Hz/-
208-230/60/1
208-230/60/1
Wire Size between ID and OD
14/4 AWG Stranded
14/4 AWG Stranded
Maximum Fuse Size
A
25
30
Minimum Circuit Amp
A
21
26
Rated Capacity
Btu/hr
24000
35000
Capacity Range
Btu/hr
6800-30700
8500-37500
Rated Power Input
W
2,182
3,500
SEER
17.0
17.0
EER
11.0
10.0
Moisture Removal
Pt./h
4.10
5.1
Rate Heating Capacity 47°F
Btu/hr
27000
37000
Heating Capacity Range
Btu/hr
6800-34100
8500-41000
Rated Power Input
W
2700
3700
HSPF
10.0
10.0
Outdoor Noise Level
dB
47
52
Dimension: Height
in (mm)
38 (965)
38 (965)
Dimension: Width
in (mm)
37 3/8(950)
37 3/8(950)
Dimension: Depth
in (mm)
14 5/8(370)
14 5/8(370)
Weight (Ship/Net)-
lbs (kg)
202.8/ 176.4 (92/80)
207.2/180.7 (94/82)
Indoor Sound Level dB
(Turbo/High/Med/Low/Quiet)
49/47/42/36/34
50/48/44/38/36
Airflow (Turbo/High/Med/Low/Quiet)
CFM
710/650/560/440/410
720/660/570/450/420
Dimension: Height
in (mm)
13 1/4(336)
14 3/8(365)
Dimension: Width
in (mm)
43 7/8(1115)
51 13/16(1316)
Dimension: Depth
in (mm)
9 9/16(243)
10 7/8(275)
Max. External Static Pressure
in.W.G(Pa)
NA
NA
Drainpipe Size O.D.
in
NA
NA
Internal Condensate Pump
NA
NA
Max. Drain-Lift height
in(mm)
NA
NA
Grill Model
NA
NA
Grill Dimension: H×W×D
in (mm)
NA
NA
Weight (Ship/Net)-
lbs (kg)
45.4/37.5(20.6/17)
55.1/46.3(25.5/21)
Connections
Flare
Flare
Liquid/Suction O.D.
in
3/8 5/8
3/8 5/8
Factory Charge
Oz
88.2
88.2
Maximum Line Length
Ft / m
165/50
165/50
Maximum Height
Ft / m
100/30
100/30
Refrigerate Line
Model Name and
Operation Range
Power Supply
Cooling
Heating
Outdoor Unit
Indoor Unit
Содержание FlexFit Pro AL24LP2VHA
Страница 1: ...SYJS 04 2017REV B Edition 2017 04 FlexFit PRO ...
Страница 8: ...FlexFit Pro 6 ...
Страница 9: ......
Страница 10: ...AW24LP2VHA AW36LP2VHA ...
Страница 11: ......
Страница 12: ...10 ...
Страница 13: ...11 ...
Страница 14: ...12 ...
Страница 15: ...13 ...
Страница 16: ...14 ...
Страница 17: ...15 ...
Страница 18: ...16 ...
Страница 19: ...17 ...
Страница 20: ...18 ...
Страница 37: ...35 FlexFit Pro ...
Страница 53: ...49 FlexFit Pro Part 5 Outdoor Units 50 2 Dimensions 53 3 Piping 55 4 Wiring diagrams 55 5 Installation 58 ...
Страница 72: ...68 FlexFit Pro 3 Outdoor PCB PCB 0151800054B Power module 0150401824 ...
Страница 90: ...86 FlexFit Pro Fig 4 1 ...
Страница 91: ...87 FlexFit Pro Fig 4 2 ...
Страница 108: ...104 FlexFit Pro 7 Controller External View of Remote Controller 7 1 Remote Controller YR HBS01 ...
Страница 121: ...Haier Commercial Air Condition Web Http www haier com Haier reserves the right to make change without any notice ...