4
Find the (3) bar feeder power wires that come
through the conduit.
Connect the power wires to the high voltage
terminals:
• red to RED [1]
• white to WHT [2]
• black to BLK [3]
Connect the ground wire [4] to the bracket for the
amplifier fan.
Find the high-voltage terminals [5] on the nearest
amplifier.
Find the high-voltage terminals [7] on the bar
feeder 30-Amp amplifier.
Install the jumpers [6] from the installation kit
between these terminals.
Connect the black wire to -H.V. Connect the red
wire to +H.V.
Install a ferrite filter P/N 64-1252 bead around the
red, white, black cables going to the bar feeder
motor.
5
Connect the current command cable, included
with the bar feeder, to the connector [1] at the
top of the amplifier.
Connect the other end of the cable:
• Connect to channel 10 (P10) [2] on the
Maincon PCB.
Find the servo motor encoder cable in the
conduit.
Connect the servo encoder cable:
• Connect to channel 10 (P26) [3] on the
Maincon PCB.
Haas Bar Feeder - Installation - NGC - AD0406