2
Set the main circuit breaker to the ON position. Press
[POWER ON]
.
Find the "Parameters" decal on the right rear panel of the bar feeder. Use a Service Key to set this parameter in
the Factory parameter tab:
• Set
parameter 13.078
BF TOOL CHANGE OFFSET.
Activate the bar feeder in the Settings page:
• Change
setting 336
Bar Feeder Enabled, to ON.
Zero return the machine.
1
Look at the transfer table [1] on the bar feeder.
The groove in the transfer table aligns with the
spindle adaptor.
Tap the frame ends [2] with a rubber mallet [3] to
move the bar feeder.
Haas Bar Feeder - Installation - NGC - AD0406