Haas Bar Feeder - Calibration Instructions
Perform this procedure one time at installation. The Run/Setup Key Switch must be in Setup Mode to calibrate the
EOB Switch.
2
The bar feeder installation is complete. Refer to the
HAAS BAR FEEDER - NGC LATHE SETUP
procedure to setup the
bar feeder.
1
Press
[RECOVERY]
button to enter the bar feeder
recovery mode.
Place a precision ground calibration bar with a
known length on the charging table.
Press
[ORIGIN]
, type in the length of the
calibration bar and press
[ENTER]
.
The pusher clears the tray then loads the
calibration bar. It will then measure the length of
the bar and apply the calibration.
Remove and properly store the calibration bar for
future use. A bar feeder only needs calibration at
installation, or if the EOB sensor, home switch, or
trolley are disassembled or replaced.
Haas Bar Feeder - Installation - NGC - AD0406
Page 13 of 13 pages