5-15
To improve the upgrading speed, you can modify the serial interface baud rate before upgrading the file.
(refer to section “
Modifying Serial Interface Parameters
” on page
). Enter
2
on the serial submenu.
The system displays the following information:
Please Start To Transfer File, Press <Ctrl+C> To Exit.
Waiting ...CCCCCCCCCC
Select and send the application file. The procedure for upgrading an application file through a serial
interface is the same as upgrading the BootWare. For details, refer to section “
Through a Ethernet/Serial Interface
.
The size of an application program is typically over 10 MB. Even at the maximum baud rate of 115200
bps, the upgrade will also take a long time. Therefore, it is not recommended to upgrade application
files through a serial interface but through an Ethernet interface.
Upgrading Applications Through an Ethernet Interface on the
BootWare Menu
Enter
3
on the BootWare main menu to enter the Ethernet submenu. For details, refer to section
“
” on page
.
Configuring Ethernet Interface Parameters
Before upgrading an application program through an Ethernet interface, you need to configure the
Ethernet interface of the access controller, as follows:
Enter
3
on the BootWare main menu to enter the Ethernet submenu. Then, enter
5
on the submenu to
enter the Ethernet interface configuration interface:
============================<ETHERNET PARAMETER SET>============================
|Note: '.' = Clear field. |
| '-' = Go to previous field. |
| Ctrl+D = Quit. |
================================================================================
Protocol (FTP or TFTP) :tftp
Load File Name :host
:main.bin
Target File Name :target
:main.bin
Server IP Address :192.168.0.1
Local IP Address :192.168.0.10
Gateway IP Address :0.0.0.0