Install the M.2 transfer module. The installation procedure is the same for an M.2 transfer
module and a SATA optical drive. For more information, see "
d.
Connect the SATA M.2 SSD cable to the system board. For more information, see
"
Connecting the SATA M.2 SSD cable
."
11.
(Optional.) Install the removed security bezel. For more information, see "
12.
Install the removed fan cage. For more information, see "
."
13.
Install the removed chassis air baffle. For more information, see "
."
14.
Install the access panel. For more information, see "
15.
Rack-mount the server. For more information, see "
16.
Connect the power cord. For more information, see "
17.
Power on the server. For more information, see "
Installing SATA M.2 SSDs at the server rear
Guidelines
You can install a maximum of two SATA M.2 SSDs on an M.2 SSD expender module. The installation
procedure for the two SSDs is the same. In this example, two SATA M.2 SSDs are installed.
Procedure
1.
Power off the server. For more information, see "
2.
Remove the server from the rack. For more information, see "
Removing the server from a rack
."
3.
Remove the access panel. For more information, see "
."
4.
Install the SATA M.2 SSD to the M.2 transfer module:
a.
Insert the connector of the SSD into the socket, and push down the other end of the SSD.
Then, fasten the screw supplied with the transfer module to secure the SSD into place, as
shown in
.
CAUTION:
To install only one SATA M.2 SSD, install it in the socket marked with J4.
b.
Connect the SATA M.2 SSD cable to the M.2 transfer module, as shown in
.