77
Figure 93 Installing the optical drive
11.
Connect the SATA optical drive cable. For more information, see "
."
12.
Install the removed security bezel. For more information, see "
13.
Install the removed fan cage. For more information, see "
."
14.
Install the removed chassis air baffle. For more information, see "
."
15.
Install the access panel. For more information, see "
16.
Rack-mount the server. For more information, see "
17.
Connect the power cord. For more information, see "
18.
Power on the server. For more information, see "
Installing a diagnostic panel
Preparing for the installation
For the installation location of the diagnostic panel, see "Front panel view."
Use
to identify the diagnostic panel to use and the diagnostic panel cable before you install
the diagnostic panel.
Table 13 Available diagnostic panel and diagnostic panel cable
Diagnostic
panel
Available server
model
Cable
SD-SFF-A 25SFF
server
The diagnostic panel comes with two cables (P/N 0404A0T1 and
P/N 0404A0SP). Determine the cable to use according to the drive
backplane:
•
If drive backplane BP-25SFF-R4900
25SFF
is used, use the
cable with P/N 0404A0T1.
•
If drive backplane BP2-25SFF-2U-G3 is used, use the cable
with P/N 0404A0SP.
SD-SFF-B 8SFF
server
The diagnostic panel comes with only one cable (P/N 0404A0T1).