72
12.
Install the removed chassis air baffle. For more information, see "
."
13.
Install the access panel. For more information, see "
14.
Rack-mount the server. For more information, see "
15.
Connect the power cord. For more information, see "
16.
Power on the server. For more information, see "
Installing the rear 2LFF drive cage
1.
Power off the server. For more information, see "
2.
Remove the server from the rack. For more information, see "
Removing the server from a rack
."
3.
Remove the access panel. For more information, see "
."
4.
Remove the chassis air baffle. For more information, see "
5.
Remove the fan cage. For more information, see "
."
6.
Remove the blank for PCIe riser connector 2, as shown in
7.
Place the rear 2LFF drive cage in the chassis and use screws to secure it into place, as shown
in
Figure 88 Installing the rear 2LFF drive cage
8.
Connect AUX signal cable, data cable, and power cord to the rear 2LFF drive backplane. For
more information, see "
."
9.
Install drives in the rear 2LFF drive cage. For more information, see "
10.
Install the removed fan cage. For more information, see "
."
11.
Install the removed chassis air baffle. For more information, see "
."
12.
Install the access panel. For more information, see "
13.
Rack-mount the server. For more information, see "
14.
Connect the power cord. For more information, see "
15.
Power on the server. For more information, see "