2
Fault/UID LED status
Present/Active LED status
Description
Off
Flashing green (4.0 Hz)
The drive is performing a RAID migration or
rebuilding, or the system is reading or
writing data to the drive.
Off
Steady green
The drive is present but no data is being
read or written to the drive.
Off
Off
The drive is not securely installed.
Table 8 NVMe drive LED description
Fault/UID LED status
Present/Active LED status
Description
Flashing amber (0.5 Hz)
Off
The managed hot removal is complete, and
you are allowed to remove the drive.
Flashing amber (4.0 Hz)
Off
The drive is in hot insertion.
Steady amber
Steady/Flashing green (4.0 Hz)
The drive is faulty. Replace the drive
immediately.
Steady blue
Steady/Flashing green (4.0 Hz)
The drive is operating correctly and is
selected by the RAID controller.
Off
Flashing green (4.0 Hz)
The drive is performing a RAID migration or
rebuilding, or the system is reading or
writing data to the drive.
Off
Steady green
The drive is present but no data is being
read or written to the drive.
Off
Off
The drive is not securely installed.
SATA M.2 SSD module LEDs
Use the LEDs on the front panel of the SATA M.2 SSD module to identify its status.
shows the location of LEDs on the front panel.
Figure 11 SATA M.2 SSD module LEDs
(1) Fault/UID LED
(2) Present/Active LED
Table 9 SATA M.2 SSD module LED description
Fault/UID LED
status
Present/Active LED
status
Description
Flashing amber (0.5
Hz)
Steady/Flashing green
(4 Hz)
An M.2 SSD module failure is predicted. As a best practice,
replace the drive before it fails.