Use a portable field service kit with a folding static-dissipating work mat.
Cooling performance
Poor cooling performance might result from improper airflow and poor ventilation and might cause
damage to the server.
To ensure good ventilation and proper airflow, follow these guidelines:
•
Install blanks if the following module slots are empty:
Drive bays.
Fan bays.
PCIe slots.
Power supply slots.
•
Do not block the ventilation openings in the server chassis.
•
To avoid thermal damage to the server, do not operate the server for long periods in any of the
following conditions:
Access panel open or uninstalled.
Air baffles uninstalled.
PCIe slots, drive bays, fan bays, or power supply slots empty.
Battery safety
The server's system board contains a system battery, which is designed with a lifespan of 3 to 5
years.
If the BIOS no longer automatically displays the correct date and time, you might need to replace the
battery. When you replace the battery, follow these safety guidelines:
•
Do not attempt to recharge the battery.
•
Do not expose the battery to a temperature higher than 60°C (140°F).
•
Do not disassemble, crush, puncture, short external contacts, or dispose of the battery in fire or
water.
•
Dispose of the battery at a designated facility. Do not throw the battery away together with other
wastes.