![H3C UniServer B5800 G3 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/h3c/uniserver-b5800-g3/uniserver-b5800-g3_user-manual_3132124013.webp)
5
Prerequisites
Take the following ESD prevention measures:
•
Wear antistatic clothing.
•
Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.
•
Do not wear any conductive objects, such as jewelry or watches.
Before removing the blade server, make sure you back up the data, stop all services, and power off
the server.
When you replace a component, examine the slot and connector for damages. Make sure the pins
are not damaged (bent for example) and do not contain any foreign objects.
You might also remove other components. For the removed components to be reinstalled correctly,
record their positions and connections before removal, for example, taking pictures of cable
connection and drive installation positions, or labeling cables.
For more information about installation principles of blade servers, see the user guide for the server.
Installing the blade server
1.
Remove the blade server blank. Press the two latches at both sides at the same time and pull
the blank out.
2.
Take the full-width blade server out of the antistatic bag.
3.
Press the buttons to release the locking levers at two sides.
4.
Insert the server into the enclosure slowly and horizontally, and then close the locking levers.
Removing the blade server
1.
Remove the full-width blade server. Press the buttons to release the locking levers at two sides,
and pull the server out of the enclosure slowly and horizontally.
2.
Put the server into an antistatic bag.