58
3.
Install the access panel. Align the standouts on the access panel with the notches in the
chassis side panels, place the access panel onto the chassis, and slide the access panel to the
server front until it is secured into place.
4.
Install the blade server.
5.
Power on the blade server. For more information, see "
Verifying the replacement
Use one of the following methods to verify that the DIMM is installed correctly:
•
Using the operating system:
In Windows, select
Run
in the
Start
menu, enter
msinfo32
, and verify the memory capacity
of the DIMM.
In Linux, execute the
cat /proc/meminfo
command to verify the memory capacity.
•
Using OM:
Log in to OM and verify the memory capacity of the DIMM. For more information, see the OM
online help.
•
Using HDM:
Log in to HDM and verify the memory capacity of the DIMM. For more information, see
H3C
Servers HDM Online Help
.
•
Using BIOS:
Access the BIOS, select
Socket Configuration
>
Memory Configuration
>
Memory
Topology
, and press
Enter
. Then, verify the memory capacity of the DIMM.
If the memory capacity displayed is inconsistent with the actual capacity, remove and then reinstall
the DIMM, or replace the DIMM with a new DIMM.
If the DIMM is in Mirror mode, it is normal that the displayed capacity is smaller than the actual
capacity.
Removing a processor
This section describes the detailed operation steps for replacing the CPU.
Operation scenario
•
The CPU fails.
•
Replace the CPU with another model.
•
The CPU hinders maintenance of other parts.