Installing a SATA M.2 SSD adapter
1.
To learn the specific installation guidelines of the SATA M.2 SSD adapter module, see "
2.
Take the SATA M.2 SSD adapter out of the antistatic bag, and insert the SATA M.2 SSDs into
the adapter.
3.
Remove the adapter blank, if any. Pressing the button on the blank to the right, pull the blank
out of the chassis.
4.
Insert the adapter into the slot on the server.
5.
(Optional.) Power on the blade server. For more information, see "
6.
(Optional) Configure RAID for the SATA M.2 SSD module. For the specific methods, see the
storage controller user guide of the product.
Replacing the NVMe VROC module
This section describes the detailed steps for replacing the NVMe VROC module.
Operation scenario
•
The NVMe VROC module fails.
•
Replace the NVMe VROC module with another model.
•
Expand the NVMe VROC module.
•
The NVMe VROC module hinders maintenance of other parts.
Prerequisites
Take the following ESD prevention measures:
•
Wear antistatic clothing.
•
Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.
•
Do not wear any conductive objects, such as jewelry or watches.
•
Before replacing, make sure that you back up the data, stop all services, and power off the
blade server. For more information, see "
•
Remove the blade server. When you replace a component, examine the slot and connector for
damages. Make sure the pins are not damaged (bent for example) and do not contain any
foreign objects.