HDM will generate SDS log records. For details on how to query the SDS log, see
H3C
Servers HDM Online Help
.
•
When the supercapacitor expires, it needs to be replaced in time. Otherwise, the power fail data
safeguard function of the storage controller will fail.
NOTE:
After replacing the expired supercapacitor, check the logical drive cache status of the storage
controller. If the logical drive cache of the storage controller is turned off, re-enable the cache related
settings to enable the power fail safeguard function. For details, see
H3C Servers HDM Online Help
.
GPU
Due to structural limitations, the GPU and the storage controller cannot be installed at the same time.
The GPU is installed on the PCIe riser card connector, and the storage controller is installed on the
storage controller connector. For the specific location of both connectors, see "
."
NIC
Standard PCIe NIC installation guidelines
Due to structural limitations, the standard PCIe NIC and the storage controller cannot be installed at
the same time. The standard PCIe NIC is connected via the riser card, which is installed on the PCIe
riser card connector, and the storage controller is installed on the storage controller connector. For
the specific location of both connectors, see "
."
Mezzanine NIC installation guidelines
•
The blade server supports installing a maximum of three mezzanine NICs.
•
When installing the mezzanine NIC, make sure the corresponding processor is present. See
" for the specific relations.
•
The mezzanine NIC and the interconnect module are interconnected through the chassis
backplane. There is a slot correspondence between them. When installing the mezzanine NIC,
ensure that the interconnect module in the corresponding slot is present. See "
" for the specific relations.
SATA M.2 SSD module
•
A SATA M.2 SSD module must be used together with a SATA M.2 SSD adapter, and the server
can install a maximum of two SATA M.2 SSD modules.
•
The SATA M.2 SSD modules are hot swappable.
•
As a best practice, install SATA M.2 SSD modules that do not contain any RAID information.