50
Solution
To resolve the issue:
1.
Verify that the power module is supplying power to the switch.
2.
Verify that the console cable is correctly connected.
3.
Verify that the console cable does not have any problems and the PC settings are correct.
4.
If the issue persists, contact H3C Support.
Garbled display
Symptom
The display on the PC is garbled.
Solution
To resolve the issue:
1.
Verify that the following settings are configured for the terminal:
{
Baud rate
—9,600.
{
Data bits
—8.
{
Parity
—None.
{
Stop bits
—1.
{
Flow control
—None.
2.
If the issue persists, contact H3C Support.
Содержание S5130-30C-HI
Страница 23: ...16 Figure 20 Mounting the switch in the rack 1 Figure 21 Mounting the switch in the rack 2...
Страница 40: ...33 Figure 46 Installing an expansion card LSWM2SP2PM Figure 47 Installing an expansion card LSPM6FWD 1 2 3 4...
Страница 51: ...44 Figure 57 Connecting the switches in one rack 1 2 3 4 5 6 7 8 9...
Страница 89: ...82 Figure 81 Airflow through the S5130 54C HI switch Figure 82 Airflow through the S5130 54QS HI switch...