31
Connecting the AC power cord for a PSR360-56A,
PSR720-56A, or PSR1110-56A power module
The following takes the PSR720-56A as an example. The connection procedure for the PSR360-56A
and PSR1110-56A is similar.
To connect the AC power cord for a PSR720-56A power module:
1.
Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.
2.
Plug the female connector end of the AC power cord into the AC input socket of the power
module (see callout 1 in
3.
Use a cable tie to secure the power cord to the handle of the power module (see callout 2 and
callout 3 in
4.
Connect the other end of the AC power cord to an AC power source.
Figure 44 Connecting the AC power cord for a PSR720-56A power module
Installing/removing an expansion card
CAUTION:
When you install or remove an expansion card, follow these guidelines:
•
Do not touch the surface-mounted components on the card directly with your hands.
•
Do not use excessive force during the installation or removal procedure.
•
If you are not to install a new card after removing the original one, install a filler panel in the slot.
•
Do not install or remove the card when the switch is operating.
The S5130-30C-HI, S5130-34C-HI, S5130-30F-HI, S5130-54C-HI, S5130-30C-PWR-HI, and
S5130-54C-PWR-HI switches each have one expansion card slot and support hot swapping of an
expansion card. For the expansion cards available for the switches, see "
."
1
2
3
Содержание S5130-30C-HI
Страница 23: ...16 Figure 20 Mounting the switch in the rack 1 Figure 21 Mounting the switch in the rack 2...
Страница 40: ...33 Figure 46 Installing an expansion card LSWM2SP2PM Figure 47 Installing an expansion card LSPM6FWD 1 2 3 4...
Страница 51: ...44 Figure 57 Connecting the switches in one rack 1 2 3 4 5 6 7 8 9...