III. Configuration procedure
1)
Configuration on Provider A
# Configure BPDU transparent transmission on Ethernet 1/0/1.
<ProviderA> system-view
[ProviderA] interface ethernet 1/0/1
[ProviderA-Ethernet1/0/1] port access vlan 2
[ProviderA-Ethernet1/0/1] stp disable
[ProviderA-Ethernet1/0/1] undo ntdp enable
[ProviderA-Ethernet1/0/1] bpdu-tunnel dot1q enable
[ProviderA-Ethernet1/0/1] bpdu-tunnel dot1q stp
2)
Configuration on Provider B
# Configure BPDU isolation on Ethernet 1/0/2.
<ProviderB> system-view
[ProviderB] interface ethernet 1/0/2
[ProviderB-Ethernet1/0/2] port access vlan 4
[ProviderB-Ethernet1/0/2] undo ntdp enable
[ProviderB-Ethernet1/0/2] bpdu-tunnel dot1q enable
3)
Configuration on Provider C
# Configure BPDU transparent transmission on Ethernet 1/0/3.
<ProviderC> system-view
[ProviderC] interface ethernet 1/0/3
[ProviderC-Ethernet1/0/3] port access vlan 2
[ProviderC-Ethernet1/0/3] stp disable
[ProviderC-Ethernet1/0/3] undo ntdp enable
[ProviderC-Ethernet1/0/3] bpdu-tunnel dot1q enable
[ProviderC-Ethernet1/0/3] bpdu-tunnel dot1q stp
# Configure BPDU transparent transmission on Ethernet 1/0/4.
[ProviderC-Ethernet1/0/3] quit
[ProviderC] interface ethernet 1/0/4
[ProviderC-Ethernet1/0/4] port access vlan 2
[ProviderC-Ethernet1/0/4] stp disable
[ProviderC-Ethernet1/0/4] undo ntdp enable
[ProviderC-Ethernet1/0/4] bpdu-tunnel dot1q enable
[ProviderC-Ethernet1/0/4] bpdu-tunnel dot1q stp