Operation Manual – OAM
H3C S3610&S5510 Series Ethernet Switches
Chapter 1 OAM Configuration
1-6
1.2.3 Configuring the Periods and Thresholds for OAM Link Error Event
Detection
Follow these steps to configure the periods and thresholds for OAM link error event
detection:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Configure the period for
error signal event
detection
oam errored-symbol
period period-value
Optional
The default is one
second.
Configure the threshold
for error signal event
detection
oam errored-symbol
threshold
threshold-value
Optional
The default is 1.
Configure the period for
error frame event
detection
oam errored-frame
period
period-value
Optional
The default is one
second.
Configure the threshold
for error frame event
detection
oam errored-frame
threshold
threshold-value
Optional
The default is 1.
Configure the period for
frame-percentage error
event detection
oam
errored-frame-period
period period-value
Optional
The default is 1,000
milliseconds.
Configure the threshold
for frame-percentage
error event detection
oam
errored-frame-period
threshold
threshold-value
Optional
The default is 1.
Configure the period for
second-percentage error
event detection
oam
errored-frame-seconds
period period-value
Optional
The default is 60 seconds.
Configure the threshold
for second-percentage
error event detection
oam
errored-frame-seconds
threshold
threshold-value
Optional
The default is 1.
Make sure the threshold
for second-percentage
error event detection is
less than the period for
second-percentage error
event detection for
second-percentage error
events to be detected.