Operation Manual – Cluster Management
H3C S3610&S5510 Series Ethernet Switches
Chapter 1 Cluster Management Configuration
1-23
III. Configuration procedure
1)
Configuring the member device (All member devices have the same configuration,
taking one member as an example)
# Enable NDP globally and for the Ethernet 1/0/1 port.
<Switch> system-view
[Switch] ndp enable
[Switch] interface Ethernet 1/0/1
[Switch-Ethernet1/0/1] ndp enable
[Switch-Ethernet1/0/1] quit
# Enable NTDP globally and for the Ethernet 1/0/1 port.
[Switch] ntdp enable
[Switch] interface Ethernet 1/0/1
[Switch-Ethernet1/0/1] ntdp enable
[Switch-Ethernet1/0/1] quit
# Enable the cluster function.
[Switch] cluster enable
2)
Configuring the management device
# Enable NDP globally and for the Ethernet 1/0/2 and Ethernet 1/0/3 ports.
<Switch> system-view
[Switch] ndp enable
[Switch] interface Ethernet 1/0/2
[Switch-Ethernet1/0/2] ndp enable
[Switch-Ethernet1/0/2] quit
[Switch] interface Ethernet 1/0/3
[Switch-Ethernet1/0/3] ndp enable
[Switch-Ethernet1/0/3] quit
# Configure the period for the receiving device to keep NDP packets as 200 seconds.
[Switch] ndp timer aging 200
# Configure the interval to send NDP packets as 70 seconds.
[Switch] ndp timer hello 70
# Enable NTDP globally and for the Ethernet 1/0/2 and Ethernet 1/0/3 ports.
[Switch] ntdp enable
[Switch] interface Ethernet 1/0/2
[Switch-Ethernet1/0/2] ntdp enable
[Switch-Ethernet1/0/2] quit
[Switch] interface Ethernet 1/0/3
[Switch-Ethernet1/0/3] ntdp enable
[Switch-Ethernet1/0/3] quit