Installation Manual
H3C SecPath F1000-S Firewall
Chapter 7 Troubleshooting
7-1
Chapter 7 Troubleshooting
7.1 Troubleshooting the Power System
Symptom
: The PWR0/PWR1 LED is OFF.
Solution
: Check that
z
The power switch of the PSU is turned on.
z
The power switch of the site power is turned on.
z
The power cord is connected correctly.
z
Required power supply is used.
Caution:
Do not hot-swap the power cord. Contact your agent if the PWR0/PWR1 LED is still
OFF after you finish the above operations.
7.2 Troubleshooting the Configuration System
If the firewall is operating normally after it is powered up, it displays the start-up
information on the console terminal. If the configuration system has failed, it displays
illegible characters or nothing at all.
I. No information on the terminal
Symptom
: The powered-up firewall displays nothing on the console terminal.
Solution
:
Step 1: Check that
z
The power system is operating normally.
z
The console cable is connected correctly.
Step 2: If you cannot locate the problem yet, check the console cable and the terminal
(HyperTerminal for example) parameter settings.
II. Illegible characters on the terminal
Symptom
: The powered-up firewall displays illegible characters on the console
terminal.
Solution
: Make sure you have set terminal (HyperTerminal) parameters as follows: