![H3C H3C SECPATH F1000-S Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/h3c/h3c-secpath-f1000-s/h3c-secpath-f1000-s_installation-manual_3117759024.webp)
Installation Manual
H3C SecPath F1000-S Firewall
Chapter 3 Hardware Installation
3-2
Caution:
Before you install your device, make sure that:
z
You have read Chapter 2 “Preparation for Installation” carefully.
z
The requirements in Chapter 2 are satisfied.
3.2 Mounting the Device
You can install your device on a workbench/tabletop or in a rack.
3.2.1 Freestanding the Device
If a standard 19-inch rack is unavailable, you can place the firewall on a clean
workbench/tabletop. To prevent any damage, observe the following:
z
Ensure the table is stable and well grounded.
z
Reserve the clearance of 10 cm (3.9 in.) around the device for adequate
ventilation.
z
Do not place any heavy stuff on the device.
3.2.2 Rack-Mounting the Device
The H3C SecPath Series Firewall can be placed in a standard 19-inch rack. Table 3-1
shows its dimensions.
Table 3-1
Dimensions of the H3C SecPath F1000-S firewall
Model
Dimensions (H
×
W
×
D)
H3C SecPath F1000-S firewall
44
×
436
×
430 mm (1.7
×
17.2
×
16.9
in.), excluding the rubber feet
Follow these steps to install the H3C SecPath F1000-S firewall:
Step 1: Check that the rack is stable enough and properly grounded. Attach the
mounting ears to the front or rear of the chassis with screws.
Step 2: Place the device on a shelf in the rack and slide it to a proper position along the
guide rails, reserving a suitable clearance between the device and the guide rails.
Step 3: Fix the brackets to the rack posts with suitable antirust pan-head screws,
making sure that the device is securely fixed.