![H3C H3C SECPATH F1000-S Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/h3c/h3c-secpath-f1000-s/h3c-secpath-f1000-s_installation-manual_3117759041.webp)
Installation Manual
H3C SecPath F1000-S Firewall
Chapter 5 Software Maintenance
5-3
I. Upgrading the application program
Step 1: Enter the Boot menu and enter
1
to download an application program using
XModem. The firewall supports the following download speeds:
Downloading application program from serial ...
Please choose your download speed:
1: 9600 bps
2: 19200 bps
3: 38400 bps
4: 57600 bps
5: 115200 bps
6: Exit to Main Menu
Enter your choice(1-6):
Step 2: Choose an appropriate download speed (for example, 115200 bps by entering
5
). The following message appears:
Download speed is 115200 bps. Change the terminal's speed to 115200 bps, and
select XModem protocol. Press ENTER key when ready.
Step 3: Change your terminal’s baud rate (see Figure 4-4) to the same baud rate for
software downloading (115200 bps in this example). After that, disconnect the terminal
([Dial-in/Disconnect]), reconnect it ([Dial-in/Dialing]), and press <Enter> to start
downloading. The system displays this message:
Downloading ... CCCCC
Note:
The new baud rate takes effect only after you reconnect the terminal emulation
program.
Step 4: Select [Transmit/Send File] in the terminal window. The following dialog box
pops up:
Figure 5-1
Send File dialog box