safety, installation and commissioning
file: n:\article\cos14310m5-v1_07hpc-en\20130207_cos14310m5-v1.07hpc-en_h-p-cosmos_treadmill_manual.doc
© 2013 h/p/cosmos sports & medical gmbh author: fh [email protected] created 07.02.2013 printed 04.03.2013 page: 79 of 197
7
Service manual
Some simple maintenance and monitoring (no repair work!), as described, can easily be done or even have to be done by
yourself. All kind of installation and repair work as well as most maintenance work is to be carried out only by trained and
authorized technicians who have been certified by h/p/cosmos. The following symbols will indicate which work can be done
by the customer and which work has to be done by authorized technicians:
The customer / user should perform this maintenance and monitoring work. Some safety checks or
monitoring (for examples of harnesses and ropes, running belt condition and position, etc.) have to be
performed on a daily basis. For this reason it is not practical to contract certified technicians for such tasks.
However, where it is practical, all maintenance and monitoring work marked with this symbol can also be
performed by certified technicians.
All installation, maintenance, repairs and monitoring work indicated with this symbol must only be
performed by trained, authorized technicians who have been certified by h/p/cosmos. Customers/users
must not perform these kinds of tasks.
We recommend calling our competent service team or entering into a maintenance contract for a routine service at an
interval of 6 or 12 months for standard machines and standard applications. A form for registration of your institution and
device is included in the delivery. In order to be able to supply you with the latest technical information and service, it is
important for you to fill out the form. Therefore please fill out the form for registration immediately and send it back.
7.1
Safety notes, warnings, precautions
7.1.1
Room conditions
N
The bearing capacity of the floor and the height in the building has to be considered before installation.
N
Install the device on a sturdy floor and take an adequate precaution to prevent the device from turning over. If the
floor is not strong enough or the installation site is not adequate, this may result in injury from the device falling or
tipping over.
N
Keep a safety zone of at least 2 m in length and the treadmills width behind the running machine and
1 x 1 m in front of the running machine. In case of reverse belt rotation, the frontal safety zone should be same
size as the rear. See chapter 5.1 entitled “Operation, General”.
N
h/p/cosmos devices must not be used outdoor and/or in environmental conditions other than those specified in the
chapter entitled „technical data“ and “Environmental requirements“, (e.g. outdoor, in wet and humid areas or a
place where it is likely to be splashed by water or rain water, swimming pools, saunas, environmental chambers,
high-pressure-, low-pressure, altitude- and oxygen-chambers, etc.). Deterioration of the insulation, current leakage
or electric shock may result.
N
The installation room has to meet the requirements of DIN and VDE installation directives.
N
Never install the device in a flammable or volatile location. This may cause explosion or fire.
N
Never install the device where acid or corrosive gases are present as current leakage or electric shock may result
due to corrosion.
N
For high performance applications a 3-phase powered treadmill and 3-phase power supply is recommended.